CD004, CD00F, CD020 (bizhub C750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
| Trouble type | CD004: Storage access error (connection failure) CD00F: Storage data transfer error CD020: Storage verify error |
| Rank | C |
| Trouble detection condition | CD004: Unable to communicate between the storage and CPU board (CPUB). CD00F: Data transfer from the storage is faulty. CD020: The data abnormality is detected by the storage verify check. |
| Trouble isolation | – |
| Relevant electrical parts | -Storage board (STRGB) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check STRGB for proper installation and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace STRGB. (Part# AA2JM72700)
- Replace CPUB. (Part# ACKNH02P03)
- Replace BASEB. (Part# ACKNH02101)
