CD00F (bizhub C360i/C300i/C250i)

You are here:

Contents

Trouble type CD00F: Storage data transfer error
RankC
Trouble detection conditionCD00F: Data transfer from the storage is faulty.
Trouble isolation
Relevant electrical parts• Storage board (STRGB) 
• CPU board (CPUB) 
• Base board (BASEB)

Procedure

  1. Check STRGB for proper installation and correct as necessary.
  2. Check CPUB for proper installation and correct as necessary.
  3. Replace STRGB. (Part# AA2JM72700)
  4. Replace CPUB. (Part# AA2JH02N06)
  5. Replace BASEB (Part# AA2JH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.18.2 (Link to the Field Service Manual)