CD00F (bizhub C360i/C300i/C250i)
Contents
| Trouble type | CD00F: Storage data transfer error |
| Rank | C |
| Trouble detection condition | CD00F: Data transfer from the storage is faulty. |
| Trouble isolation | – |
| Relevant electrical parts | • Storage board (STRGB) • CPU board (CPUB) • Base board (BASEB) |
Procedure
- Check STRGB for proper installation and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace STRGB. (Part# AA2JM72700)
- Replace CPUB. (Part# AA2JH02N06)
- Replace BASEB (Part# AA2JH02005)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.18.2 (Link to the Field Service Manual)
