CD010 (C4751i)

You are here:

Contents

Trouble typeCD010: Storage unformat
RankC
Trouble detection conditionUnformatted storage is connected.
Trouble isolation
Relevant electrical partsStorage board (STRGB)CPU board (CPUB)Base board (BASEB)

Procedure

  1. Check STRGB for proper installation and correct as necessary.
  2. Check CPUB for proper installation and correct as necessary.
  3. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [Format] and perform the function.
  4. Replace STRGB.
  5. Replace CPUB.
  6. Replace BASEB.

(Link to the Field Service Manual)