CD050 (bizhub C360i/C300i/C250i)
Contents
Trouble type | CD050: Storage recovery timeout |
Rank | C |
Trouble detection condition | The storage fails to recover from the power save mode within the predetermined period of time. |
Trouble isolation | – |
Relevant electrical parts | • Storage board (STRGB) • CPU board (CPUB) • Base board (BASEB) |
Procedure
- Check STRGB for proper installation and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Reinstall STRGB.
- Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [Format] and perform the function.
- Replace STRGB. (Part# AA2JM72700)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.18.9 (Link to the Field Service Manual)