CD050 (bizhub C360i/C300i/C250i)

You are here:

Contents

Trouble typeCD050: Storage recovery timeout
RankC
Trouble detection conditionThe storage fails to recover from the power save mode within the predetermined period of time.
Trouble isolation
Relevant electrical parts• Storage board (STRGB)
• CPU board (CPUB)
• Base board (BASEB)

Procedure

  1. Check STRGB for proper installation and correct as necessary.
  2. Check CPUB for proper installation and correct as necessary.
  3. Reinstall STRGB.
  4. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [Format] and perform the function.
  5. Replace STRGB. (Part# AA2JM72700)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.18.9 (Link to the Field Service Manual)