How Can We Help?

CD201, CD202, CD203 (bizhub 4750i/4050i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeCD201: File memory mounting error

CD202: Memory capacity discrepancy

CD203: Memory capacity discrepancy 2
RankC
Trouble detection conditionCD201:
– The file memory is not mounted.

– The file has any abnormality.
CD202:
– File memory capacity on the CPU board (CPUB) is not enough.

– File memory capacity necessary for duplex printing is not enough.
CD203:
File memory capacity on the CPU board (CPUB) is not enough.
Trouble isolation
Relevant electrical parts-CPU board (CPUB)
-Base board (BASEB)

Procedure

  1. Check CPUB for proper installation and correct as necessary.
  2. Replace CPUB. (Part# ACT9H01003)
  3. Replace BASEB.
    4750i (Part# ACT9H02013)
    4050i (Part# ACT9H02002)

(Link to the Field Service Manual)

Table of Contents