How Can We Help?

CD211 (bizhub 364e/284e/224e)

You are here:

Contents

Trouble type PCI-SDRAM DMA operation failure
Trouble code CD211
Rank C
Detection timing Hardware related to the transfer of memory image of the MFP board (MFPB) fails to respond.
Trouble isolation
Relevant electrical parts MFP board (MFPB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Replace MFPB.MFPB (Part# A61FH02005)

Document Information ID D0001128005 Revise ID R000003

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.16.11 (Link to the Field Service Manual)

Table of Contents