CD211 (bizhub C364e/C284e/C224e)
Contents
Trouble type | PCI-SDRAM DMA operation failure |
Trouble code | CD211 |
Rank | C |
Detection timing | Hardware related to the transfer of memory image of the MFP board (MFPB) fails to respond. |
Trouble isolation | – |
Relevant electrical parts | MFP board (MFPB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Replace MFPB. (Part# A5C1H0200B) | – | – |
- Link to the layout drawings for related parts by each trouble code (S.74. C5372, C6901, C6902, C6903, CA051, CA052, CA053, CC170 – CC186, CC191 – CC214, CC216, CD211, CD212, CD241, CD242, CD252 – CD271, CD401 – CD413, CE001, CE003 – CE305, CEEE1)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.16.11 (Link to the Field Service Manual)