CD211, CD212 (bizhub 650i/550i/450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | CD211: PCI-SDRAM DMA operation failure CD212: Compression/extraction timeout detection |
Rank | C |
Trouble detection condition | CD211: Hardware related to the transfer of memory image of the CPU board (CPUB) fails to respond. CD212: Hardware related to the BTC compression function of the CPU board (CPUB) fails to respond. |
Trouble isolation | – |
Relevant electrical parts | -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check CPUB for proper installation and correct as necessary.
- Replace CPUB.
650i/550i (Part# AC74H02P03)
450i (Part# AC76H02P02) - Replace BASEB. (Part# AC74H02101)