How Can We Help?
CD252 (bizhub C658/C558/C458/C368/C308/C258)
Contents
Trouble type | CD252: No relay board for IC-416 mounting at IC-416 mount setting |
Rank | C |
Trouble detection condition | EFI relay circuit boards (VI-508 or VI-510) are not mounted when the IC-416 is set to mount setting at Service Mode. |
Trouble isolation | – |
Relevant electrical parts | • MFP board (MFPB) • EFI relay board (VI-508 or VI-510) |
Procedure
- If the IC-416 is not mounted, access [Service Mode] -> [System 2] -> [Image Controller Setting] and check to see if �??Controller 0�?? is set for image controller.
- Check the EFI relay board (VI-508 or VI-510) connector for proper connection and correct as necessary.
- Replace EFI relay board (VI-508 (Part# A7PUH02801) or VI-510 (Part# A79JH02800)).
- Replace MFPB. (bizhub C368/C308/C258 Part# A7PUH02123 / bizhub C658/C558/C458 (C458 Part# A79MH02102 / C558 or C658 Part # A79JH02102))
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.24.21 (Link to the Field Service Manual)