How Can We Help?

CD252 (bizhub C658/C558/C458/C368/C308/C258)

You are here:

Contents

Trouble typeCD252: No relay board for IC-416 mounting at IC-416 mount setting
RankC
Trouble detection conditionEFI relay circuit boards (VI-508 or VI-510) are not mounted when the IC-416 is set to mount setting at Service Mode.
Trouble isolation
Relevant electrical parts• MFP board (MFPB)
• EFI relay board (VI-508 or VI-510)

 Procedure

  1. If the IC-416 is not mounted, access [Service Mode] -> [System 2] -> [Image Controller Setting] and check to see if �??Controller 0�?? is set for image controller.
  2. Check the EFI relay board (VI-508 or VI-510) connector for proper connection and correct as necessary.
  3. Replace EFI relay board (VI-508 (Part# A7PUH02801) or VI-510 (Part# A79JH02800)).
  4. Replace MFPB. (bizhub C368/C308/C258 Part# A7PUH02123 / bizhub C658/C558/C458 (C458 Part# A79MH02102 / C558 or C658 Part # A79JH02102))

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.24.21 (Link to the Field Service Manual)

Table of Contents