CD252 (bizhub C754e/C654e)

You are here:

Contents

Trouble typeNo relay circuit boards for IC-414 mounting at IC-414 mount setting
Trouble codeCD252
RankC
Detection timingEFI relay board (EFIRYB; VI-506) are not mounted when the IC-414 is set to mount setting at Service Mode.
Trouble isolation
Relevant electrical parts• MFP board (MFPB)
• E FI relay board (EFIRYB; VI-506)

 (2)Procedure

StepActionControl signalLocation of electrical components
1If the IC-414 is not mounted, access [Service Mode] -> [System 2] -> [Image Controller Setting] and check to see if “Controller 0” is set for [Image Controller Setting].
2Check the EFI relay board (EFIRYB; VI-506) connector for proper connection and correct as necessary.
3Replace the EFI relay board (EFIRYB; VI-506) (Part# AA2JH02800)
4Replace MFPB (Part# A2X0H02015)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.16.12 (Link to the Field Service Manual)