How Can We Help?

CD272 (bizhub C554/C454)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typei-Option activated and additional memory and HDD not installed
Trouble codeCD272
RankC
Detection timingWhile the i-Option is activated, the additional memory included in UK-204 and the HDD are not installed.
Trouble isolation
Relevant electrical parts-MFP board (MFPB)
-Hard disk
-Memory board/2 (MEMB/2; UK-204)

(2)Procedure

StepActionControl signalLocation of electrical components
1Check MEMB/2 for proper connection and correct as necessary.
2Access [Service Mode] -> [System 2] -> [HDD] and check to see if Installed is selected.
3Replace MEMB/2 (Part# V865300066)
4Replace the hard disk. (Part# A2X0M72C00)
5Replace MFPB. (Part# A2XKH02004)

K3.16.14 (Link to the Field Service Manual)

Table of Contents