CD313 (bizhub 360i/300i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | CD313: TPM key data error |
Rank | C |
Trouble detection condition | A fault occurs in the TPM key data. |
Trouble isolation | – |
Relevant electrical parts | – |

Procedure
- Touch [Recover Data] displayed at the lower right portion on the trouble screen.
- A screen confirming whether to recover data appears.
- Select [Yes].
- The screen will be shifted to the data restoration screen to perform data restoration.
NOTE- When the restoration is performed in a short time, data restoration screen may not be displayed.
- Check the message which indicates that the data restoration was successfully conducted. Turn OFF the main power switch and turn it ON again more than 10 seconds after.
NOTE- In case it failed to restore data, return to the trouble code screen.
- Replace the current TPMB with a new one. (Part# AA2JH02T00)
- Replace the current CPUB with a new one. (Part# AC77H02P02)
- Replace the current BASEB with a new one. (Part# AC77H02101)
NOTE
- Nonvolatile data backup will be automatically performed every hour. Backup can also be performed manually with the following setting. [Service Mode] -> [Enhanced Security] -> [Memory Data Backup]