How Can We Help?

CD3A0 (bizhub 287/227)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeCD3A0: Counter error
RankC
Trouble detection conditionThe total counter values provided by the MFP board (MFPB) and the eMMC board (eMMC) are different.
Trouble isolation
Relevant electrical parts-MFP board (MFPB)
-eMMC board (eMMC)

 Procedure

  1. If this error occurs temporarily due to the use of the board removed from another machine, reinstall the original board.
  2. Replace the current MFPB with a new one. (Part# A7AHH0201D)
  3. Replace the current eMMC with a new one. (Contact Konica Minolta technical support if the eMMC board needs to be replaced.)

K.3.18.23 (Link to the Field Service Manual)

Table of Contents