CD703 (bizhub C4000i/C3300i)
Contents
Trouble type | CD703: FW download communication fault |
Rank | C |
Trouble detection condition | Irregular data is received during FW downloading. • Places are changed in the order of write completion pulses. • A write completion pulse is received for a memory for which binary writing is not permitted. • Final checksum mismatch in FW download • Two-minute timeout (no response from CTL, the number of transfer data items less than the specified) |
Trouble isolation | – |
Relevant electrical parts | • CPU board (CPUB) • Base board (BASEB) |
Procedure
- Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power switch.
- Check CPUB for proper installation and correct as necessary.
- Rewrite the firmware.
- Replace CPUB. (C4000i Part# Part# AAJRH01005 / C3300i Part# AAJTH01005)
- Replace BASEB. (Part# AAJRH02005)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.14.24 (Link to the Field Service Manual)