CDF51 (bizhub 364e/284e/224e)

You are here:

Contents

Trouble type ASIC image version failure (back side)
Trouble code CDF51
Rank C
Detection timing <When DF-701 is installed> Communication error is detected between the MFP board (MFPB) and the dual scan image processing board (DSIPB).
Trouble isolation
Relevant electrical parts • MFP board (MFPB)
• Dual scan image processing board (DSIPB; DF-701)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Check the connector between MFPB and DSIPB for proper connection, and correct as necessary.
2 Update the firmware.
3 Replace DSIPB
DF-701 (Part# A161H02A00)
4 Replace MFPBMFPB (Part# A61FH02005)

Document Information ID D0001128033 Revise ID R000004

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.