How Can We Help?

CDFA1 (bizhub 658e/558e/458e)

You are here:

Contents

Trouble typeCDFA1: ASIC image error (back side)
RankC
Trouble detection conditionCommunication error is detected between the MFP board (MFPB) and the dual scan image processing board (DSIPB).
Trouble isolation
Relevant electrical parts• MFP board (MFPB) 
• Dual scan image processing board (DSIPB)

Procedure

  1. Check the connector between MFPB CN24-DSIPB CN1 for proper connection and correct as necessary.
  2. Rewrite the firmware.
  3. Replace DSIPB. (Part# A9HGH02A00)
  4. Replace MFPB. (658e/558e Part# AA6RH02103 / 458e Part# AA6UH02101)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.25.40. (Link to the Field Service Manual)