Trouble typeCE002: Message and method parameter failure
RankC
Trouble detection conditionCPU board (CPUB) is faulty.
Trouble isolation
Relevant electrical partsStorage board (STRGB)CPU board (CPUB)Base board (BASEB)

Procedure

  1. Turn OFF the main power switch and turn it ON again, and conduct the following setting. [Service Mode] -> [System 1] -> [Initialization] -> [Clear All Data].
  2. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [Format] and perform the function.
  3. Replace STRGB.
  4. Replace CPUB.
  5. Replace BASEB.

(Link to the Field Service Manual)