Trouble type | CE013: Virus scan engine startup failure (8 GB storage) |
Rank | C |
Trouble detection condition | When the virus scan settings are effective, change from storage board (STRGB) to microSD (8 GB). |
Trouble isolation | – |
Relevant electrical parts | microSD |
Procedure
- Replace the microSD (16 GB)(Contact Konica Minolta technical support if this needs to be replaced. ) or STRGB (Part# AA2JM72700).
- Reboot the machine.