How Can We Help?

CE101 (958/808)

You are here:

Contents

Trouble typeCE101: Browser finish detected
RankC
Trouble detection conditionThe browser is automatically recovered (restarted) after the main body detected that the browser (separate process) has stopped with fault.When the Malfunction finish is detected over predetermined number of times or the browser task process is except in idle (printing, etc).
Trouble isolation
Relevant electrical partsMFP board (MFPB)

Procedure

  1. Check the connectors on MFPB for proper connection and correct as necessary.
  2. Replace MFPB. MFPB (Part# A796H02015)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.18.3. (Link to the Field Service Manual)