CE101 (bizhub C4000i/C3300i)

You are here:

Contents

Trouble typeCE101: Browser finish detected
RankC
Trouble detection condition• The browser is automatically recovered (restarted) after the main body detected that the browser (separate process) has stopped with fault.
• When the Malfunction finish is detected over predetermined number of times or the browser task process is except in idle (printing, etc.).
Trouble isolation
Relevant electrical parts• CPU board (CPUB)
• Base board (BASEB)

Procedure

  1. Check the connectors on BASEB for proper connection and correct as necessary.
  2. Replace CPUB.CPUB (Part# C3300i AAJTH01005 C4000i AAJRH01005)
  3. Replace BASEB.BASEB (Part# AAJRH02005)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.15.3. (Link to the Field Service Manual)