CE101 (C4751i)

You are here:

Contents

Trouble typeCE101: Browser finish detected
RankC
Trouble detection conditionThe browser is automatically recovered (restarted) after the main body detected that the browser (separate process) has stopped with fault.When the “Malfunction finish is detected over predetermined number of times” or “the browser task process is except in idle (printing, etc.)”.
Trouble isolation
Relevant electrical partsCPU board (CPUB)Base board (BASEB)

Procedure

  1. Check the connectors on BASEB for proper connection and correct as necessary.
  2. Replace CPUB.
  3. Replace BASEB.

(Link to the Field Service Manual)