Trouble typeCE201: Transmission operation log storage fault
RankC
Trouble detection conditionWhen the transmission log storage failed, it repeats retrial until transmission operation log is stored. The trouble is detected when the retrial failed for predetermined number of times.
Trouble isolation
Relevant electrical partsMFP board (MFPB)

Procedure

  1. Check the connectors on MFPB for proper connection and correct as necessary.
  2. Replace MFPB. (bizhub 368e/308e / bizhub 658e/558e/458e)(658e/558e Part# AA6RH02103 / 458e Part# AA6UH02101 / 368e/308e Part# AA6VH02101)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.26.4. (Link to the Field Service Manual)