CE201 (bizhub 950i/850i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | CE201: Transmission operation log storage fault |
Rank | C |
Trouble detection condition | When the transmission log storage failed, it repeats retrial until transmission operation log is stored. The trouble is detected when the retrial failed for predetermined number of times. |
Trouble isolation | – |
Relevant electrical parts | – CPU board (CPUB) – Base board (BASEB) |
Procedure
- Check the connector connection on BASEB and correct as necessary.
- Replace CPUB.
- Replace BASEB.