Trouble typeTransmission operation log storage fault
Trouble codeCE201
RankC
Detection timingWhen the transmission log storage failed, it repeats retrial until transmission operation log is stored. 
The trouble is detected when the retrial failed for predetermined number of times.
Trouble isolation
Relevant electrical partsMFP board (MFPB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connectors on MFPB for proper connection and correct as necessary.
2Replace MFPB. (Part# A5C1H0200B)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.17.4 (Link to the Field Service Manual)