Trouble typeCE201: Transmission operation log storage fault
RankC
Trouble detection conditionWhen the transmission log storage failed, it repeats retrial until transmission operation log is stored. The trouble is detected when the retrial failed for predetermined number of times.
Trouble isolation
Relevant electrical parts-CPU board (CPUB)
-Base board (BASEB)

Procedure

  1. Check the connectors on BASEB for proper connection and correct as necessary.
  2. Replace CPUB. (Part# ACKNH02P03)
  3. Replace BASEB. (Part# ACKNH02101)

(Link to the Field Service Manual)