CE301 (bizhub C554e/C454e)
CE301 Contents
Trouble type | Referring incorrect memory |
Trouble code | CE301 |
Rank | C |
Detection timing | Error occurred with the process inside the MFP controller |
Trouble isolation | – |
Relevant electrical parts | MFP board (MFPB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connectors on MFPB for proper connection and correct as necessary. | – | – |
2 | Replace MFPB Part #A5C1H0200B PWB assembly(PWB-MFP) | – | – |
3 | Acquire the debug logs in [Service Mode] -> [Debug Settings] and analyze them. | – | – |
- Link to the layout drawings for related parts by each trouble code (S.117. C6901- C6903, CA051 – CA053, CC151, CC152, CC170 – CC186, CC191 – CC214, CC216, CD211, CD212, CD241, CD242, CD252 – CD271, CD401- CD413, CE001, CE003 – CE007, CE101, CE201, CE301 – CE305, CEEE1)
Document Information ID D0000998852 Revise ID R000002
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
(Link to the Field Service Manual) K.3.17.5 CE301