CE302 (bizhub 364e/284e/224e)
Contents
Trouble type | Incorrect command |
Trouble code | CE302 |
Rank | C |
Detection timing | Error occurred with the process inside the MFP controller |
Trouble isolation | – |
Relevant electrical parts | MFP board (MFPB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connectors on MFPB for proper connection and correct as necessary. | – | – |
2 | Replace MFPBMFPB (Part# A61FH02005) | – | – |
3 | Acquire the debug logs in [Service Mode] -> [Debug Settings] and analyze them. | – | – |
- Link to the layout drawings for related parts by each trouble code (S.62. C5372, C6901, C6902, C6903, CA051, CA052, CA053, CC170 – CC186, CC191 – CC214, CC216, CD211, CD212, CD241, CD242, CD261, CD262, CD271, CD401 – CD413, CE001, CE003 – CE305, CEEE1)
Document Information ID D0001128043 Revise ID R000003
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.17.5 (Link to the Field Service Manual)