How Can We Help?

CE302 (bizhub C4050i/C3350i)

You are here:

Contents

Trouble typeCE302: Incorrect command
RankC
Trouble detection conditionError occurred with the process inside the MFP controller.
Trouble isolation
Relevant electrical parts• CPU board (CPUB) 
• Base board (BASEB)

Procedure

  1. Check the connectors on BASEB for proper connection and correct as necessary.
  2. Replace CPUB.CPUB (Part# A93EH01004)
  3. Replace BASEB.BASEB (Part# A93EH02007)
  4. Acquire the debug logs in [Service Mode] -> [Debug Settings] and analyze them.

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.18.9. (Link to the Field Service Manual)

Table of Contents