Skip to main content

CE304 (bizhub C554e/C454e)

You are here:

CE304 Contents

Trouble type Finished due to error outside Qt library
Trouble code CE304
Rank C
Detection timing Error occurred with the process inside the MFP controller
Trouble isolation –
Relevant electrical parts MFP board (MFPB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Check the connectors on MFPB for proper connection and correct as necessary. – –
2 Replace MFPB Part #A5C1H0200B PWB assembly(PWB-MFP) – –
3 Acquire the debug logs in [Service Mode] -> [Debug Settings] and analyze them. – –

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

(Link to the Field Service Manual) K.3.17.5 CE304