Trouble typeCE305: Program forced to stop
RankC
Trouble detection conditionError occurred with the process inside the MFP controller.
Trouble isolation
Relevant electrical partsMFP board (MFPB)

Procedure

  1. Check the connectors on MFPB for proper connection and correct as necessary.
  2. Replace MFPB. (bizhub 368/308 / bizhub 558/458)(558 Part# A9HGH02102 / 458 Part# A9HHH02102 / 368/308 Part# A9HJH02102)
  3. Acquire the debug logs in [Service Mode] -> [Debug Settings] and analyze them.

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.