How Can We Help?

CED01 (bizhub 658e/558e/458e/368e/308e)

You are here:

CED01 (bizhub 658e/558e/458e/368e/308e)

Contents

Trouble typeCED01: The authentication application information does not exist in the hard disk/eMMC board in the enhanced server authentication state.
RankC
Trouble detection conditionWith â??Enhanced Server Authenticationâ?? set, no authentication application registration information is found in the hard disk or the eMMC board (eMMCB).
Trouble isolation
Relevant electrical parts• eMMC board (eMMCB)
• Hard disk (A) (HDD (A))
• Hard disk (B) (HDD (B): HD-524)

Procedure

  1. Turn OFF and ON the main power switch.
  2. Check the connector from MFPB to hard disk for proper connection and correct as necessary.
  3. Check the connector from eMMCB to MFPB for proper connection and correct as necessary.
  4. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [Format] -> [Logical Format] and perform the function.
  5. Replace the hard disk. (HDD (A) (bizhub 368e/308e / bizhub 658e/558e/458e) / HDD (B)) (HDD(A) 658e/558e/458e/368e/308e Part# A5C1M72H00 / HDD (B) Part# A2X0M72C00)
  6. If the above actions do not solve the problem, contact KM.

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.26.9. (Link to the Field Service Manual)

Table of Contents