How Can We Help?

CEEE2 (bizhub C754/C654)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeScanner section malfunction
Trouble codeCEEE2
RankA
Detection timingA scanner part is faulty.
Trouble isolation
Relevant electrical parts-LED exposure unit (LA201)
-CCD board (CCDB)
-Scanner drive board (SCDB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Correct the connector connection between CCDB and MFPB if faulty.
2Replace SCDB (Part# A2X0H01A01Old or Part# A2X0H01A12)
3Replace CCDB (A2X0R70022Old or A2X0R72100)
  • Link to the layout drawings for related parts by each trouble code (S.119. CEEE2)