P-34 (bizhub 750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Malfunction type | Atmospheric pressure sensor failure |
Malfunction code | P-34 |
Malfunction detection timing | An error of the atmospheric pressure sensor (ATMPRS) is detected. |
Relevant parts | -Atmospheric pressure sensor (ATMPRS) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the connector between ATMPRS-BASEB CN27E for proper connection and correct as necessary.
- Clean the cover on ATMPRS, if it is dirty.
- Replace CPUB. (Part# ACV7H02P02)
- Replace BASEB. (Part# ACV7H0210)