P-39 (bizhub C650i/C550i/C450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Malfunction type | Paper exit cooling fan failure (When OT-513, JS-508, or FS-533+MK-607 is installed) |
Malfunction code | P-39 |
Malfunction detection timing | The fan lock signal remains Low for a predetermined continuous period of time while the fan is turning. |
Relevant parts | -Paper exit cooling fan (FM23) -Expansion control board (EXCB) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the connector between FM23-relay CN710-EXCB CN15EX for proper connection and correct as necessary.
- Check the connector between EXCB CN2EX-BASEB CN12E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace FM23. (Contact Konica Minolta technical support if this needs to be replaced.)
- Replace EXCB. (Part# AA2JH00500)
- Replace CPUB. (C650i Part# AA7NH02P03 / C550i Part# AA7PH02P01 / C450i Part# AA7RH02P02)
- Replace BASEB. (Part# AA2JH02005)
L.2.19 (Link to the Field Service Manual)