P-40 (bizhub 650i/550i/450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Malfunction type | Fusing motor torque failure |
Malfunction code | P-40 |
Malfunction detection timing | When the printing ends, the fusing motor torque exceeds the predetermined value. |
Relevant parts | -Fusing motor (M3) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the connector between M3-BASEB CN19E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace M3. (Part# AA2JM11100)
- Replace CPUB.
650i/550i (Part# AC74H02P03)