S-1 (bizhub C360i/C300i/C250i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Malfunction type | CCD gain adjustment failure |
Malfunction code | S-1 |
Malfunction detection timing | It is detected that the CCD clamp gain adjustment value is faulty. |
Relevant parts | LED exposure unitCCD unitScanner drive board (SCDB)Base board (BASEB) |
Procedure
- Correct the connector connection between CCDB CN2-BASEB CN6 if faulty.
- Check for possible extraneous light and correct as necessary.
- Clean the lens, mirrors, CCD surface, and shading sheet if dirty.
- Correct reflective mirror of the scanner if faulty, or change scanner mirror.
- Replace the CCD unit. (Part# AA2JR70100)
- Replace SCDB. (Part# AA2JH01A00)
- Replace BASEB. (Part# AA2JH02005)
L.2.3 (Link to the Field Service Manual)