C4301 (bizhub 754e/654e)
Contents
Trouble type | PH cooling fan failure to turn |
Trouble code | C4301 |
Rank | B |
Detection timing | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | • PH cooling fan (FM14) • PH relay board (PHRYB) • Printer control board (PRCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between FM14-relay CN202-PHRYB CN12 for proper connection and correct as necessary. | – | – |
2 | Check the fan for possible overload and correct as necessary. | – | – |
3 | FM14 operation check | PHRYB CN12-8 (DRIVE)PHRYB CN12-9 (LOCK) | 9-B |
4 | Replace FM14 (Part# 9J03M10000) | – | – |
5 | PHRYB ICP1 conduction check | – | – |
6 | Replace PHRYB (Part# A55VH00300) | – | – |
7 | Replace PRCB (Part# A55VH00105) | – | – |
- Link to the wiring diagram (N.1. bizhub 754e/654e)
- Link to the layout drawings for related parts by each trouble code (S.80. C4301)
Document Information ID D0001104790 Revise ID R000003
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.9.3 (Link to the Field Service Manual)