C0202 (bizhub C658/C558/C458)
Contents
Trouble type | C0202: Tray 1 feeder up/down abnormality |
Rank | B |
Trouble detection condition | The tray 1 upper limit sensor (PS25) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 1 |
Relevant electrical parts | •Tray 1 lift-up motor (M12) •Tray 1 upper limit sensor (PS25) •MFP board (MFPB) |
Procedure
- Remove thetray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M12-MFPB CN27E for proper connection and correct as necessary.
- Check the connector of M12 for proper drive coupling and correct as necessary.
- Check the connector between PS25-relay CN30-MFPB CN34E for proper connection and correct as necessary.
- PS25 I/O check, sensor check
- Control signal: MFPB CN34E<B>-3 (ON)
- Location of electrical component: 27-J
- M12 operation check
- Control signal: MFPB CN27E-5 (M12_24V)
- Location of electrical component: 19-J
- Replace M12. (Part# 9J06M10300)
- MFPB F1E conduction check
- Replace MFPB. (C458 Item# 9 Part# A79MH02102 / C558 or C658 Item # 9 Part # A79JH02102)
NOTICE
- Link to the wiring diagram (bizhub C658/C558/C458)
Please verify all parts for accuracy and current version.