92-03 (bizhub 754e/654e)

You are here:

Contents

JAM typeDuplex pre-registration section
JAM code92-03
Detection timingThe OHP sensor (PS40) is not turned ON even after the lapse of a given period of time after a duplex paper feed sequence has been started.
Misfeed processing location• Upper right door 
• Duplex door
Relevant parts• ADU transport motor/1 (M31) 
• ADU transport motor/2 (M32) 
• Registration sensor (PS38) 
• OHP sensor (PS40) 
• Paper feed/transport drive board (PFTDB) 
• Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical component
1Initial check items
2PS38 I/O check, sensor checkPFTDB CN3-6 (ON)4-P
3PS40 I/O check, sensor checkPFTDB CN3-3 (ON)4-P
4M32 operation checkPFTDB CN4-10 to 138-P
5M31 operation checkPFTDB CN4-14 to 178-P
6PFTDB ICP3 or ICP11 conduction check
7Replace PFTDB (Part# A2X0H00202)
8PRCB ICP13 conduction check
9Replace PRCB (Part# A55VH00105)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.1.11.1 (Link to the Field Service Manual)