75-43 (bizhub C360i/C300i/C250i)
Contents
| JAM type | Misfeed at RU section | ||||
| JAM code | 75-43 | ||||
| JAM detection timing | <When FS-536 or FS-536SD is installed> The RU entrance sensor (PS2) is not turned OFF (unlocked) even after the lapse of a given period of time after PS2 is turned ON (blocked). | ||||
| Misfeed processing location | Horizontal transport cover | ||||
| Relevant parts | • RU entrance sensor (PS2) • FS control board (FSCB) |
Procedure
| Step | Action | Control signal | Location of electrical component |
|---|---|---|---|
| 1 | Initial check items | – | – |
| 2 | PS2 I/O check, sensor check | FSCB J6-7 (ON) | FS-536/FS-536SD 12-K |
| 3 | Replace FSCB. (FS-536(SD) Part# A87GPP0V00) | – | – |
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.1.9.19 (Link to the Field Service Manual)