Trouble type | IH input power error |
Trouble code | C3B07 |
Rank | A |
Detection timing | • While the IH heater was ON, input power stayed at the high voltage power detection value or over for more than the predetermined period of time. • While the IH heater was ON, input power was at the low power detection value or under for more than the predetermined period of time. • While the IH heater was ON, input power was at the high voltage detection value or over for more than the predetermined period of time. • While the IH heater was ON, input power was below the low voltage detection value or under for more than the predetermined period of time. • While the IH heater was ON, inverter power stayed at the upper limit value or over for more than the predetermined period of time. • While the IH heater was ON, output voltage halt was detected. |
Trouble isolation | – |
Relevant electrical parts | • IH coil unit (FH1) • IH power supply (IHPU) • Noise filter (NF1) • Printer control board (PRCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connection of the fusing unit. | – | – |
2 | Check the fusing unit, IH coil unit, IHPU, NF1 and PRCB for proper connection and correct or change as necessary. | – | – |
3 | Replace the IH coil unit (Part# A2X0M40200) | – | – |
4 | Replace IHPU (Part# A61DM40A00) | – | – |
5 | Replace PRCB (Part# A2X0H00S06) | – | – |
6 | Replace NF1 (Part# A2XKM40J00) | – | – |