92-40 (bizhub C364e/C284e/C224e)
Contents
| JAM type | Misfeed at duplex pre-registration section |
| JAM code | 92-40 |
| Detection timing | For the second-side feed of paper in the duplex mode, the image write start signal permit continues to be disabled for a predetermined period of time after the timing of the image write start signal output. |
| – | In case paper position is detected as locating properly after main power switch is turned ON, door and cover are opened / closed or jam/trouble reset is done, it is regarded as paper jam at duplex pre-registration section. |
| Misfeed processing location | Right door |
| Relevant parts | -Transport motor (M1) -ADU transport clutch (CL6) -Registration sensor (PS1) -Front side board (FRB) -Printer control board (PRCB) |
(2)Procedure
| Step | Action | Control signal | Location of electrical component |
| 1 | Initial check items | – | – |
| 2 | PS1 I/O check, sensor check | FRB CN8-3 (ON) | 4 to 5-L |
| 3 | CL6 operation check | PRCB CN12-11 (ON) | 26-C |
| 4 | M1 operation check | PRCB CN31-2 (REM)PRCB CN31-5 (LOCK) | bizhub C364e 21-Jbizhub C284e 22-Jbizhub C224e 24-J |
| 5 | Replace FRB (Part# A7PUH00500) | – | – |
| 6 | Replace PRCB (Part# A5C1H00102) | – | – |
- Link to the wiring diagram (N.1. bizhub C364e/C284e/C224e)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.1.11.1 (Link to the Field Service Manual)