Trouble type | C2558: Abnormally high toner density detected black TCR sensor |
Rank | B |
Trouble detection condition | TC ratio in the imaging unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively. |
Trouble isolation | – |
Relevant electrical parts | -Imaging unit/C,M,Y,K -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Reinstall the imaging unit.
- Check the connector between the imaging unit/C-relay CN5-EXCB CN14E for proper connection and correct as necessary. (C2552)
- Check the connector between the imaging unit/M-relay CN8-EXCB CN14E for proper connection and correct as necessary. (C2554)
- Check the connector between the imaging unit/Y-relay CN7-EXCB CN14E for proper connection and correct as necessary. (C2556)
- Check the connector between the imaging unit/K-relay CN6-EXCB CN14E for proper connection and correct as necessary. (C2558)
- Check CPUB for proper installation and correct as necessary.
- Replace the corresponding imaging unit. (Part# AAJV01E)
- Replace CPUB. (Part# AAJRH01005)
- Replace BASEB. (Part# A93EH02007)