C6756 (bizhub C3320i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C6756: CIS power-supply voltage malfunction |
Rank | C |
Trouble detection condition | Power is not supplied to CIS after the lapse of a given period of time after the main power switch or power key is turned ON or the machine recovers from the sleep mode. |
Trouble isolation | – |
Relevant electrical parts | -CIS module (IR CIS) -CIS relay board (CISRYB) -DC power supply (DCPS) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the connector between IR CIS-CISRYB CN1 for proper connection and correct as necessary.
- Check the connector between CISRYB CN2-BASEB CN6 for proper connection and correct as necessary.
- Check the connector between BASEB CN2E-DCPS CN5 for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- Replace IR CIS. (Part# AAJPR70500)
- Replace CISRYB. (Part# AAJPH10100)
- Replace CPUB. (Part# AAJRH01005)
- Replace BASEB. (Part# A93EH02007)
- Replace DCPS. (Part# AAJRR70600)
L.3.11.9 (Link to the Field Service Manual)