C5306 (bizhub C754/C654)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | IH coil cooling fan’s failure to turn |
Trouble code | C5306 |
Rank | B |
Detection timing | The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning. |
Trouble isolation | – |
Relevant electrical parts | -IH coil cooling fan (FM3) -Printer control board (PRCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between FS3-relay CN324-PRCB CN2 for proper connection and correct as necessary. | – | – |
2 | Check the fan for possible overload and correct as necessary. | – | – |
3 | FM3 operation check | PRCB CN2-8 (DRIVE)PRCB CN2-9 (LOCK) | 3-K |
4 | Replace FM3 (Part# 9313100072) | – | – |
6 | Replace PRCB (Part# A2X0H00102) | – | – |
- Link to the wiring diagram (N.1. bizhub C754/C654)
- Link to the layout drawings for related parts by each trouble code (S.84. C5306)
K.3.10.3 (Link to the Field Service Manual)