C9402 (bizhub C754/C654)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
| Trouble type | Exposure LED lighting abnormally |
| Trouble code | C9402 |
| Rank | A |
| Detection timing | The average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job. |
| Trouble isolation | Scanner |
| Relevant electrical parts | -LED exposure unit (LA201) -Flat cable (LED exposure unit) -CCD board (CCDB) -Scanner drive board (SCDB) -MFP board (MFPB) |
(2)Procedure
| Step | Action | Control signal | Location of electrical components |
| 1 | Check the machine type information registered and re-enter as necessary.For details the machine information, see J.2.4 Entering the machine type information. | ||
| 2 | Check the connection between SCDB and LA201, and correct if necessary. | – | – |
| 3 | Check the connection between SCDB and MFPB, and correct if necessary. | – | – |
| 4 | Check that the connection between CCDB and MFPB, and correct if necessary. | – | – |
| 5 | Replace the LED exposure unit (Part# A161M31001Old or Part# A2X0M31000) | – | – |
| 6 | Replace CCDB (A2X0R70022Old or A2X0R72100) | – | – |
| 7 | SCDB F1 conduction check | – | – |
| 8 | Replace SCDB (Part# A2X0H01A01Old or Part# A2X0H01A12) | – | – |
| 9 | Replace MFPB (Part# A2XKH02004) | – | – |
- Link to the layout drawings for related parts by each trouble code (S.108. C9401, C9402)
K.3.13.1 (Link to the Field Service Manual)
