CD252 (bizhub C364/C284/C224)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
| Trouble type | No relay circuit boards for IC-414 mounting at IC-414 mount setting |
| Trouble code | CD252 |
| Rank | C |
| Detection timing | EFI relay circuit boards (VI-506) are not mounted when the IC-414 is set to mount setting at Service Mode. |
| Trouble isolation | – |
| Relevant electrical parts | -MFP board (MFPB) -EFI relay board (VI-506) |
(2)Procedure
| Step | Action | Control signal | Location of electrical components |
| 1 | If the IC-414 is not mounted, access [Service Mode] -> [System 2] -> [Image Controller Setting] and check to see if Controller 0 is set for [Image Controller Setting]. | – | – |
| 2 | Check the EFI relay board (VI-506) connector for proper connection and correct as necessary. | – | – |
| 3 | Replace EFI relay board (VI-506) (Part# A161H02801) | – | – |
| 4 | Replace MFPB. (C364/C284 Part# A161H02104 / C224 Part# A4FMH02208) | – | – |
- Link to the layout drawings for related parts by each trouble code (S.73. C5372, C6901, C6902, C6903, CA051, CA052, CA053, CC170 – CC186, CC191 – CC214, CC216, CD211, CD212, CD241, CD242, CD252 – CD271, CD401 – CD412, CE001, CE003 – CEEE1)
K3.16.11 (Link to the Field Service Manual)