C1109 (bizhub C658/C558/C458)
Contents
Trouble type | C1109: Stapler motor drive malfunction | ||
Rank | B | ||
Trouble detection condition | <When FS-533 is installed> | The stapler home sensor (PS110) is not turned ON (blocked) even after the set period of time has elapsed after the stapler motor turned ON. | |
<When FS-536 or FS-536SD is installed> | •The stapler home position sensor (rear) (PS23) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the stapler motor turned ON. • The stapler position sensor (center) (PS24) is turned ON (blocked), when the stapler motor is running. | ||
<When FS-537 or FS-537SD is installed> | •The stapler home position sensor (PS18/PS19) is not turned OFF (unblocked) or ON (blocked) even after the set period of time has elapsed after the stapler motor (M5) turned ON. • The stapler position sensor (center) (PS20) is turned ON (blocked), when the stapler motor (M5) is running. |
Trouble isolation | Staple | ||
Relevant electrical parts | <When FS-533 is installed> | •Stapler home sensor (PS110)Stapler unit • Stapler relay board (STREYB)FS control board (FSCB) | |
<When FS-536 or FS-536SD is installed> | •Stapler unitStapler home position sensor (rear) (PS23) • Stapler position sensor (center) (PS24) • FS control board (FSCB) | ||
<When FS-537 or FS-537SD is installed> | •Stapler unitStapler home position sensor (corner) (PS18) • Stapler home position sensor (rear) (PS19) • Stapler position sensor (center) (PS20) • FS control board (FSCB) |
Procedure
When FS-533 is installed
- Check the connector between the stapler unit-STREYB CN122, CN123 for proper connection and correct as necessary.
- Check the connector of the stapler unit for proper drive coupling and correct as necessary.
- Check the connector between PS110-FSCB CN110 for proper connection and correct as necessary.
- PS110 I/O check, sensor check
- Control signal: FSCB CN110
- Location of electrical component: FS-533 8-D to E
- Replace the stapler unit. (Part# A2YUPPK401 )
- Replace STREYB. (Part # A2YUPPG700)
- Replace FSCB. (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2))
NOTICE
- Link to the wiring diagram (FS-533)
When FS-536 or FS-536SD is installed
- Check the connector between the stapler unit-relay CN4-FSCB J11 for proper connection and correct as necessary.
- Check the connector of the stapler unit for proper drive coupling and correct as necessary.
- Check the connector between PS23-relay CN3-FSCB J11 for proper connection, and correct as necessary.
- Check the connector between PS24-relay CN3-FSCB J11 for proper connection and correct as necessary.
- PS23 I/O check, sensor check
- Control signal: FSCB J11<B>-3 (ON)
- Location of electrical component: FS-536/FS-536SD 4-C
- PS24 I/O check, sensor check
- Control signal: FSCB J11<B>-6
- Location of electrical component: FS-536/FS-536SD 5-C
- Replace the stapler unit. (Part# A3EP560100)
- Replace FSCB. (Part# A87GPP1400)
NOTICE
- Link to the wiring diagram (FS-536/FS-536SD)
When FS-537 or FS-537SD is installed
- Check the connector between the stapler unit-FSCB J17 for proper connection and correct as necessary.
- Check the connector of the stapler unit for proper drive coupling and correct as necessary.
- Check the connector between PS18-FSCB J16 for proper connection and correct as necessary.
- Check the connector between PS19-FSCB J16 for proper connection and correct as necessary.
- Check the connector between PS20-FSCB J16 for proper connection and correct as necessary.
- PS18 I/O check, sensor check
- Control signal: FSCB J16-9
- Location of electrical component: FS-537/FS-537SD 15-D
- PS19 I/O check, sensor check
- Control signal: FSCB J16-6
- Location of electrical component: FS-537/FS-537SD 15-D
- PS20 I/O check, sensor check
- Control signal: FSCB J16-3
- Location of electrical component: FS-537/FS-537SD 15-D
- Replace the stapler unit. (Part# A07P790100)
- Replace FSCB. (Part# A87HPPAG00)
NOTICE
- Link to the wiring diagram (FS-537/FS-537SD)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.10.10 (Link to the Field Service Manual)