17-20 (bizhub C750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
| JAM type | Misfeed at external LCT transport section (When LU-205 or LU-303 is installed) | |
| JAM code | 17-20 | |
| JAM detection timing | 17-20: The tray 2 vertical transport sensor (PS19) is not turned ON even after the lapse of a given period of time after the paper has turned ON the paper feed sensor (PS3). | |
| Paper jam of a sheet of paper left at the external LCT transport section results, if the LU paper feed sensor (PS3) is turned ON when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset. | ||
| Misfeed processing location | Right bottom door | |
| Relevant parts | -LU transport motor (M3) -Tray 2 vertical transport motor (M23) -LU paper feed sensor (PS3) -Tray 2 vertical transport sensor (PS19) -LU drive board (LUDB) -Base board (BASEB) |
Procedure
| Step | Action | Control signal | Location of electrical component |
|---|---|---|---|
| 1 | Initial check items | – | – |
| 2 | PS3 I/O check, sensor check | LUDB CN5-8 (ON) | LU-205 / LU-303 4-G |
| 3 | PS19 I/O check, sensor check | BASEB CN23E-8 (ON) | 16-K |
| 4 | M3 load check Check code: 28 Multi code: 46, 49, 50 | LUDB CN4-1 to 4 | LU-205 / LU-303 3-G |
| 5 | M23 load check Check code: 28 Multi code: 36, 39, 40 | BASEB CN31E-5 to 8 | 23-K |
| 6 | Replace LUDB. (LU-205 Part# A8H6H00100 / LU-303 Part# A8H6H00100) | – | – |
| 7 | Replace BASEB. (Part# ACKNH02101) | – | – |