P-39 (bizhub 750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Malfunction type | Tacking fan failure |
Malfunction code | P-39 |
Malfunction detection timing | The fan lock signal is detected continuously for a predetermined period of time while the fan is turning. |
Relevant parts | -Tacking fan/Fr (FM23) -Tacking fan/Rr (FM24) -Expansion control board (EXCB) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Check the connector between FM23-relay CN711-relay CN710-EXCB CN15EX, FM24-relay CN404-relay CN403-relay CN401-EXCB CN8EX for proper connection and correct as necessary.
- Check the fan for possible overload and correct as necessary.
- FM23 conduction check.
- Control signal: EXCB CN15EX-4 (REM), EXCB CN15EX-6 (LOCK)
- Location of electrical component: 26-X
- FM24 conduction check.
- Control signal: EXCB CN8EX-11 (REM), EXCB CN8EX-13 (LOCK)
- Location of electrical component: 21-X
- Replace the defective fan. (FM23 (Part# A93EM10000) / FM24 (Part# A93EM10000)
- Replace EXCB. (Part# AC74H00501)